Iei-integration S12A v1.12 Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 110
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
SAILORPC-12A Panel PC
Page 47
Mode Setting [Full On Mode]
Use the Mode Setting option to configure the second fan.
Î
Full On Mode DEFAULT
Fan is on all the time
Î
Automatic mode
The fan adjusts its speed using these settings:
Temp. Limit of OFF
Temp. Limit of Start
Fan Start PWM
Slope PWM 1
Î
PWM Manual mode
The fan spins at the speed set in:
Fan PWM control
Temp. Limit of OFF [000]
WARNING:
CPU failure can result if this value is set too high
The fan will turn off if the temperature falls below this value.
Minimum Value: 0°C
Maximum Value: 127°C
Temp. Limit of Start [020]
WARNING:
CPU failure can result if this value is set too high
When the fan is off, it will only start when the temperature exceeds this setting.
Minimum Value: 0°C
Maximum Value: 127°C
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 109 110

Comentarios a estos manuales

Sin comentarios