Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Smart Fan Mode Configuration
FAN 1 Smart Fan Control [Auto Duty-Cycle Mode]
Temperature 1 60
Temperature 2 50
Temperature 3 40
Temperature 4 30
Duty Cycle 1 85
Duty Cycle 2 70
Duty Cycle 3 60
Duty Cycle 4 50
FAN 2 Smart Fan Control [Auto Duty-Cycle Mode]
Temperature 1 60
Temperature 2 50
Temperature 3 40
Temperature 4 30
Duty Cycle 1 85
Duty Cycle 2 70
Duty Cycle 3 60
Duty Cycle 4 50
FAN 3 Smart Fan Control [Auto Duty-Cycle Mode]
Temperature 1 60
Temperature 2 50
Temperature 3 40
Temperature 4 30
Duty Cycle 1 85
Duty Cycle 2 70
Duty Cycle 3 60
Duty Cycle 4 50
Smart Fan Mode Select
---------------------
: Select Screen
↑ ↓: Select Item
Enter Select
+ - Change Opt.
F1 General Help
F2 Previous Values
F3 Optimized Defaults
F4 Save & Exit
ESC Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 16: FAN 1 Configuration
FAN 1 Smart Fan Control [Auto Duty-Cycle Mode]
Use the FAN 1 Smart Fan Control option to configure the FAN 1 Smart Fan.
Manual RPM
Mode
The fan spins at the speed set in Manual by
RPM settings
Manual Duty
Mode
The fan spins at the speed set in Manual by Duty
Cycle settings
Auto RPM Mode
The fan adjusts its speed using Auto by RPM
settings