Iei-integration NANO-LX v1.10 Manual de usuario Pagina 223

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 232
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 222
NANO-LX EPIC SBC
ENTER.
Step 2: The Data on RAID drives will be erased (Y/N) confirm box appears. Press Y.
Step 0:
E.5.7 Rebuild RAID Array
The Rebuild RAID Array option can rebuild a RAID array if a member of a RAID
configuration should fail. Neither RAID0 nor JBOD provides data redundancy. The
Rebuild RAID Array option only applies to RAID1 arrays and is applicable when a
member of a RAID1 configuration has failed.
Step 1: Use the arrow keys to highlight Rebuild RAID Array and press E
NTER. A
flashing ‘R’ appears at the list of existing arrays. The source and destination
drives will be displayed.
Step 2: Press Y to begin the rebuild process. Step 0:
NOTE:
A status bar will indicate the rebuild progress. Rebuild consumes
considerable system resources and the time required for rebuilding a RAID
array may vary depending on the size of stored data, disk drive capacity, and
drive performance.
E.5.8 Select Boot Drive
Step 1: Use the arrow keys to highlight Select Boot Drive and press ENTER. A flashing
‘A’ appears at the Drive Menu where the boot drive can be chosen.
Step 2: Press E
NTER or the space bar to finish the configuration. Step 0: