Iei-integration NOVA-945GSE v1.01 Manual de usuario Pagina 133

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 195
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 132
NOVA-945GSE 5.25” SBC
Page 133
Resume On RTC Alarm [Disabled]
Use the Resume On RTC Alarm option to specify the time the system should be roused
from a suspended state.
Disabled D
EFAULT
The real time clock (RTC) cannot generate a wake
event
Enabled
If selected, the following appears with values that
can be selected:
RTC Alarm Date (Days)
System Time
After setting the alarm, the computer turns itself on
from a suspend state when the alarm goes off.
6.3.7 Remote Configuration
Use the Remote Access Configuration menu (834HBIOS Menu 10) to configure remote
access parameters. The Remote Access Configuration is an AMIBIOS feature and
allows a remote host running a terminal program to display and configure the BIOS
settings.
Vista de pagina 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 194 195

Comentarios a estos manuales

Sin comentarios